  1. alldodge

    Removal / Fitting Duoprop

    Same with B3 and understand your concern
  2. alldodge

    2 bottom bolt loops on y pipe broken

    If there is enough left may still be good
  3. alldodge

    Removal / Fitting Duoprop

    Don't know the dimensions I set my elbow for torque on props, and never had one loosen or come off
  4. alldodge

    2005 Rinker 232 Cuddy...water in Cuddy

    I have same model just 1995 Should be bow up (just slightly is enough) with plug out for storage
  5. alldodge

    2005 Rinker 232 Cuddy...water in Cuddy

    If its on a trailer then it can come from the bilge. If the water tank is full it can come from it leaking Sitting outside could be rain
  6. alldodge

    1989/1990 4.3 distributor

    You should be able to take it apart and get it going again. Just depends how much labor you want to put in it
  7. alldodge

    LED Bulb trips breaker

    I have 2 other voltmeters with up to 10 amp max. The unit didn't trip (fan off switch on), so I turned the fan on and will see if it trips this 24 hours. The PS on the basement FP is what I made from my old Palm device. It has 2 outputs, 6V and I forget the other. Being old should mean made...
  8. alldodge

    LED Bulb trips breaker

    Circuit tracer, never used one but should make finding everything connected easier i guess
  9. alldodge

    1989/1990 4.3 distributor

    Get a Delco EST kit
  10. alldodge

    LED Bulb trips breaker

    Turned other side of the 3-2 breaker off and think I found every outlet. Check those and found nothing really bad. Did find one which didn't have a ground wire, so the common was jumpered to it, and no ground wire in the metal box. Had the power on all day and night yesterday and no trip...
  11. alldodge

    LED Bulb trips breaker

    Tried that, went out to the shop and got my clamp meter and it wasn't working, hadn't been used in many years. Open it up and battery leaked and damaged it. Might get another for one time use
  12. alldodge

    LED Bulb trips breaker

    Have done that, post 11 and 12
  13. alldodge

    Ford 289 intake manifold

    Just casting and machining difference. When the man was designed it needed X depth for bolt threads for a bolt length Y. My guess is the man might be a bit thinner at that location so it wasn't drilled as far but still has enough thread to hold
  14. alldodge

    LED Bulb trips breaker

    Yes, same as the one running the basement fire place So far has not tripped
  15. alldodge

    Can you search DMV records for a particular car

    Need a COP friend so he/she could look them up
  16. alldodge

    I don't think this will buff out....

    Maybe not, but the way it was breaking its real thin ice with snow on top
  17. alldodge

    LED Bulb trips breaker

    Put PS on extension cord to another breaker Turned fan on and this afternoon it tripped again, so its the fan/fan control or the split outlet. Have not gotten into the outlet yet. Turn fan off at the wall switch, so only the new weather station PS is connected
  18. alldodge

    Winter Storage/Cover with Radar Arch . . .

    We have 8 inches, abnormal for us. At least its stopped and going to rain this weekend