  1. alldodge

    TWIN 1994 VOLVO PENTA 8.2 OVERHEATING

    Get a short piece of clear hose from the hardware store, couple clamps and double barbed fitting. Hose should be 1.25 inch inside diameter Remove the hose coming from the raw water pump at the thermostat and place the clear hose between hose and thermostat housing. Run the motor and look for...
  2. alldodge

    Volvo Penta 4.3gxi-f

    Yes its pin 4 a Tan/Blue wire. I don't have wiring for GXi-F but do have for the D model and it shows wire going to J1-8
  3. alldodge

    Sewing Marine Vinyl?

    Paging Ted can you come to the front office please @tpenfield
  4. alldodge

    Gas turning milky

    Happened twice in 7 years, I would look at where your buying gas.
  5. alldodge

    Leaving Tampa, Osprey, Fort Myers ? ?

    Wife's Aunt checked in (Englewood), tree fell on house so it will be a long time. Ins paying for hotel room, house needs to be gutted. Everyone is ok so life goes on
  6. alldodge

    Engine cooling water in tube bigger than gimbal housng tube

    Did find it this time, and it comes as a kit only https://www.mercruiserparts.com/96246a4-hose On the other hand being a Alpha drive it can use heavy duty heater hose. It doesn't need hard walled suction line like if it was on a Bravo. A Gen 2 uses molded hose...
  7. alldodge

    Engine cooling water in tube bigger than gimbal housng tube

    Would it be this? https://www.mercruiserparts.com/816597a1-coupling-assy It list for Gen 2
  8. alldodge

    Engine cooling water in tube bigger than gimbal housng tube

    Might be right, then what is the correct part?
  9. alldodge

    Mercruiser 5.0 crankshaft front oil seal replacement

    Nothing special, remove and replace My question would be what caused it to start leaking, for it to leak is rare. Wonder if its a cracked cover, but hey can be seen once balancer is removed
  10. alldodge

    What is the next logical step?

    Unplug the Bat charger Disconnect one of the Bats Negative lead See if the same crank situation happens, and if it does reconnect the one and disconnect the other and try again Once you know which Bat does it, swap the Bats location or its leads to find out if its the Bat or the Bat switch
  11. alldodge

    Mercmonitor

    The install manual shows a 3 amp fuse built into the harness http://www.livorsi.com/pdf/merc%20monitor%20installation.pdf
  12. alldodge

    Riddle me this Batman.....

    Could get a $3 AF tester
  13. alldodge

    complete Alpha one Gen one retrofit into older boat.

    Missed the "clamp on" forks I have a set of them which I use on my Terramite. The clamp on type can be dangerous because they can pivot side ways. Maybe put them direct next to each other and clamp them so they are more ridged
  14. alldodge

    1988 3.0 and 1994 3.0 swap

    The balancer shows its a 140hp 3.0
  15. alldodge

    Radon and seal concrete under tub

    House built in 1969, probably before Radon was wildly known. This is my Great Aunt/Uncle retirement home and now its ours. Just decided to test it about a year ago. Found somewhat higher readings with the package tester so bought the higher tech electronic unit. Now just want to try some...
  16. alldodge

    Radon and seal concrete under tub

    I can see the entire underside of the front of the tub. If I had a concrete pumper of some kind that might work. Could mix it up real soupy but not sure this would make more a mess then something else I wonder Get some 3 LB foam and setup something I can pour from the rear to the front. The...
  17. alldodge

    Radon and seal concrete under tub

    Will do what I have to do, but that much epoxy looks to be maybe $500
  18. alldodge

    Radon and seal concrete under tub

    Wonder how many gallons it would take Figure a standard tub is 30x60 and don't know if the rear is higher then what I can see. I do have a bore scope so with enough lighting I should be able to make a guess
  19. alldodge

    Radon and seal concrete under tub

    Maybe, like it better then something like Tar. Wounder would expansion and contraction be an issue?
  20. alldodge

    Radon and seal concrete under tub

    In short: Measuring Radon between 4.1 to 4.5 Basement Tub was installed over gravel base. Concrete is all around it and as to why they did it this way is anyone's guess. Have access to drain side of tub and looking for a way to seal under the tub without removing the tub. Think about floor...